Test Code MYCOPT Mycoplasma pneumoniae, IgM, Serum (Rapid)

Performing Laboratory

Huntsville Hospital Laboratory/Madison Hospital Laboratory

Specimen Requirements

Draw blood in a plain, red-top tube(s) or a serum gel tube(s). Spin down and send 1 mL (minimum volume:  0.5 mL) of serum refrigerated within 4 hours of draw. 

Specimen Stability Information

 

Specimen Type

Temperature

Time

Serum

Refrigerated

 72 hrs

 

Reference Values

Negative

Day(s) Set Up

Monday through Sunday

LOINC Coding

 

Test Name LOINC Code

Mycoplasma pneumoniae Ab.IgM

22427-9

 

 

Methodology

Enzyme immunoassay (EIA)

CPT Coding

86738

Secondary ID

HHA1560